— MEDIA CENTRE

Technical notes and company news

Selection and installation Damping, in detail Plant and team
技术文章

Replacing a damper? Measure these four things and you will get it right the first time

Replacing a buffer goes wrong when "roughly the same" is good enough. Measure four things properly, photograph them clearly, and your supplier can match it first time.

Read
技术文章

Rebounder or magnetic catch? Choosing the right fitting for a handleless cabinet

Both let you press a door open. Service life, feel, noise and installation are entirely different — pick the wrong one and the complaint arrives in three months.

Read
技术文章

The slide already runs smoothly — so why add a buffer at all?

A buffer is not there to make a slide smoother. It is there to take control of the last stretch — the one that decides whether a drawer goes "slam" or "click".

Read
技术文章

Gas spring vs. damper vs. rebounder: which one does your mechanism need?

The three names get used interchangeably, but they do opposite jobs: one pushes a door up, one slows a door down, and one springs a door open. Choose the wrong one and every parameter you tune afterwards is wasted.

Read
技术文章

Soft-close stopped working? Check these in order — it is usually not the damper

A drawer that slams, that soft-closes only sometimes, or that feels sticky at the end — do not replace parts yet. Work through these five checks in order and you will usually find the real cause.

Read
技术文章

How to choose the stroke: it is not a number you can just pick

Too short a stroke and the damper never gets time to act — the drawer still slams. Too long and you waste space for no benefit. There is really one criterion: the damper has to engage before the drawer starts losing speed.

Read
技术文章

Buffer not working after installation? Check these four details first

The same buffer can feel like two different products depending on how it is fitted. Position, alignment, clearance, and the slide's own end stop — get one wrong and no parameter tuning will help.

Read
技术文章

Three damping modes: constant, variable and energy-absorbing

The same damper family can behave in completely different ways as the stroke advances. Pick wrong and the door springs back, or drops with a jolt at the end. Three force-stroke curves explain the difference.

Read
技术文章

Pull-out force and return time: the two numbers to settle first

Many enquiries stall on "what force do you offer". Both pull-out force and return time are tunable — the real question is what feel you need, not which number we hold.

Read
技术文章

What "unspecified tolerances to GB/T 1804-f" means

It reads like boilerplate, but it sets the basis for quotation and acceptance. Understanding it saves a lot of arguing later.

Read
公司动态

Together in 2026: our Chinese New Year gathering

A workshop turned into a banquet hall, a lion dance, awards for the people who earned them, colleagues performing for colleagues — and everyone squeezed into one photo at the end.

Read

Technical notes are drawn from our drawing specifications and production experience; where a specific model is involved, its drawing governs.